TPIC44L02 4 通道串聯(lián)/并聯(lián)低側(cè)前置 FET 驅(qū)動(dòng)器

數(shù)據(jù):

描述

The TPIC44L01, TPIC44L02, and TPIC44L03 are low-side predrivers that provide serial and parallel input interfaces to control four external FET power switches such as offered in the TI TPIC family of power arrays. These devices are designed primarily for low-frequency switching, inductive load applications such as solenoids and relays. Fault status for each channel is available in a serial-data format. Each driver channel has independent off-state open-load detection and on-state shorted-load/short-to-battery detection. Battery overvoltage and undervoltage detection and shutdown is provided on the TPIC44L01/L02. On the TPIC44L03 driver, only over-battery voltage shutdown is provided. Each channel also provides inductive-voltage-transient protection for the external FET.

These devices provide control of output channels through a serial input interface or a parallel input interface. A command to enable the output from either interface enables the respective channels gate output to the external FET. The serial interface is recommended when the number of signals between the control device and the predriver must be minimized and the speed of operation is not critical. In applications where the predriver must respond very quickly or asynchronously, the parallel input interface is recommended.

For serial operation, the control device must transition CS\ from high to low to activate the serial input interface. When this occurs, SDO is enabled, fault data is latched into the serial interface, and the fault flag is refreshed.

Data is clocked into the serial registers on low-to-high transitions of SCLK through SDI. Each string of data must consist of at least four bits of data. In applications where multiple devices are cascaded together, the string of data must consist of four bits for each device. A high data bit turns the respective output channel on and a low data bit turns it off. Fault data for the device is clocked out of SDO as serial input data is clocked into the device. Fault data consists of fault flags for shorted-load and open-load flags (bits 0\x963) for each of the four output channels. A high bit in the fault data indicates a fault and a low bit indicates that no fault is present for that channel. Fault register bits are set or cleared asynchronously to reflect the current state of the hardware. A fault must be present when CS\ is transitioned from high to low to be captured and reported in the serial fault data. New faults cannot be captured in the serial register when CS\ is low. CS\ must be transitioned high after all of the serial data has been clocked into the device. A low-to-high transition of CS\ transfers the last four bits of serial data to the output buffer puts SDO in a high-impedance state and clears and reenables the fault register. The TPIC44L01/L02/L03 was designed to allow the serial input interfaces of multiple devices to be cascaded together to simplify the serial interface to the controller. Serial input data flows through the device and is transferred out SDO following the fault data in cascaded configurations.

For parallel operation, data is transferred directly from the parallel input interface IN0-IN3 to the respective GATE(0\x963) output asynchronously. SCLK or CS\ is not required for parallel control. A 1 on the parallel input turns the respective channel on, where a 0 turns it off. Note that either the serial input interface or the parallel input interface can enable a channel. Under parallel operation, fault data must still be collected through the serial data interface.

The predrivers monitor the drain voltage for each channel to detect shorted-load or open-load fault conditions in the the on and off states respectively. These devices offer the option of using an internally generated fault-reference voltage or an externally supplied fault-reference voltage through VCOMP for fault detection. The internal fault reference is selected by connecting VCOMPEN to GND and the external reference is selected by connecting VCOMPEN to VCC. The drain voltage is compared to the fault reference when the channel is turned on to detect shorted-load conditions and when the channel is off to detect open-load conditions. When a shorted fault occurs using the TPIC44L01 or the TPIC44L03, the channel is turned off and a fault flag is sent to the control device as well as to the serial fault register bits. If a fault occurs while using the TPIC44L02, the channel transitions into a low-duty cycle, pulse-width-modulated (PWM) signal as long as the fault is present. Shorted-load fault conditions must be present for at least the shorted-load deglitch time, t(STBDG), to be flagged as a fault. A fault flag is sent to the control device as well as the serial fault register bits. More detail on fault detection operation is presented in the device operation section of this data sheet.

These devices provide protection from over-battery voltage and under-battery voltage conditions irrespective of the state of the output channels. When the battery voltage is greater than the overvoltage threshold or less than the undervoltage threshold, all channels are disabled and a fault flag is generated. Battery-voltage faults are not reported in the serial fault data. The outputs return to normal operation once the battery-voltage fault has been corrected. When an over-battery/under-battery voltage condition occurs, the device reports the battery fault, but disables fault reporting for open- and shorted-load conditions. Fault reporting for open- and shorted-load conditions are reenabled after the battery fault condition has been corrected.

These devices provide inductive transient protection on all channels. The drain voltage is clamped to protect the FET. The clamp voltage is defined by the sum of VCC and turnon voltage of the external FET. The predriver also provides a gate-to-source voltage (VGS) clamp to protect the gate-source terminals of the power FET from exceeding their rated voltages. An external active low RESET\ is provided to clear all registers and flags in the device. GATE(0\x963) outputs are disabled after RESET\ has been pulled low.

These devices provide pulldown resistors on all inputs except CS\ and RESET\. A pullup resistor is used on CS\ and RESET\.

特性

  • 4通道串并輸入低側(cè)預(yù)FET驅(qū)動(dòng)器
  • 器件可級(jí)聯(lián)
  • 外部功率FET的內(nèi)部55V電感負(fù)載鉗位和V GS 保護(hù)鉗
  • 所有漏極端子上的獨(dú)立短路負(fù)載/電池短路故障檢測
  • 獨(dú)立的斷態(tài)開路故障檢測
  • 電池過壓鎖定保護(hù)和故障報(bào)告
  • TPIC44L01的電池欠壓鎖定保護(hù)和TPIC44L02
  • 異步漏極開路故障標(biāo)志
  • 器件輸出可與多個(gè)器件進(jìn)行線或通
  • 通過串行輸出端子返回故障狀態(tài)
  • < li>器件和外部RESET端子的內(nèi)部全局上電復(fù)位
  • 具有遲滯的高阻抗CMOS兼容輸入
  • TPIC44L01和TPIC44L03在發(fā)生短路負(fù)載故障時(shí)禁用門控輸出發(fā)生
  • TPIC44L02將門輸出轉(zhuǎn)換為低占空比PWM模式發(fā)生短路故障

參數(shù) 與其它產(chǎn)品相比?低端驅(qū)動(dòng)

? Number of channels (#) Power switch Peak output current (A) Input VCC (Min) (V) Input VCC (Max) (V) Rise time (ns) Fall time (ns) Prop delay (ns) Input threshold Channel input logic Input negative voltage (V) Features Rating Operating temperature range (C) Package Group ? TPIC44L02 4 ? ? MOSFET ? ? 0.0012 ? ? 8 ? ? 24 ? ? 3500 ? ? 3000 ? ? 5000 ? ? CMOS ? ? Non-Inverting ? ? -0.3 ? ? SPI Interface
Sleep Mode
OVP
Fault Diagnostics ? ? Catalog ? ? -40 to 125 ? ? SSOP | 24 ? ?

技術(shù)文檔

數(shù)據(jù)手冊(1)
元器件購買 TPIC44L02 相關(guān)庫存

相關(guān)閱讀

主站蜘蛛池模板: 一区二区三区在线观看视频 | 国产高清免费午夜在线视频 | 日韩精品在线一区二区 | 欧美第四色 | 天天干天天操天天碰 | 成人黄色免费网站 | 国产网站在线播放 | 亚洲五月六月丁香激情 | 色小视频| 亚洲午夜精品久久久久 | 国产精品国产三级国产普通话对白 | 超黄视频网站 | 在线免费影视 | 日韩一级片在线免费观看 | 国产亚洲精品久久久久久久软件 | 女主播扒开内衣让粉丝看个够 | 丁香花在线 | 失禁h啪肉尿出来高h受 | 播放欧亚一级特黄录像 | 国产在线97色永久免费视频 | 日本不卡毛片一二三四 | 亚洲第一页在线 | 中文天堂资源在线www | 黄色888| 1024你懂的日韩 | 日韩美女影院 | 亚洲一级毛片免费看 | 欧美12一13高清视频 | 狠狠婷婷 | 亚洲综合成人在线 | 天天干天天操天天爽 | 久草免费新视频 | 四虎国产精品永久地址51 | 午夜情趣视频 | 午夜毛片在线观看 | 午夜欧美成人久久久久久 | 日本不卡专区 | 日本不卡毛片一二三四 | 97影院理论在线观看 | 五月天停婷基地 | 日本暴力喉深到呕吐hd |