在线观看www成人影院-在线观看www日本免费网站-在线观看www视频-在线观看操-欧美18在线-欧美1级

0
  • 聊天消息
  • 系統(tǒng)消息
  • 評(píng)論與回復(fù)
登錄后你可以
  • 下載海量資料
  • 學(xué)習(xí)在線課程
  • 觀看技術(shù)視頻
  • 寫文章/發(fā)帖/加入社區(qū)
會(huì)員中心
創(chuàng)作中心

完善資料讓更多小伙伴認(rèn)識(shí)你,還能領(lǐng)取20積分哦,立即完善>

3天內(nèi)不再提示

TPIC46L01 6 通道串聯(lián)/并聯(lián)低端前置 FET 驅(qū)動(dòng)器

數(shù)據(jù):

描述

The TPIC46L01, TPIC46L02, and TPIC46L03 are low-side predrivers that provide serial input interface and parallel input interface to control six external field-effect transistor(FET) power switches such as offered in the Texas Instruments TPIC family of power arrays. These devices are designed primarily for low-frequency switching, inductive load applications such as solenoids and relays. Fault status for each channel is available in a serial-data format. Each driver channel has independent off-state open-load detection and on-state shorted-load/short-to-battery detection. Battery overvoltage and undervoltage detection and shutdown are provided. Battery and output load faults provide real-time fault reporting to the controller. Each channel also provides inductive-voltage-transient protection for the external FET.

These devices provide control of output channels through a serial input interface or a parallel input interface. A command to enable the output from either interface enables the respective channel GATE output to the external FET. The serial input interface is recommended when the number of signals between the control device and the predriver must be minimized, and the speed of operation is not critical. In applications where the predriver must respond very quickly or asynchronously, the parallel input interface is recommended.

For serial operation, the control device must transition CS\ from high to low to activate the serial input interface. When this occurs, SDO is enabled, fault data is latched into the serial input interface, and the FLT\ flag is refreshed.

Data is clocked into the serial registers on low-to-high transitions of SCLK through SDI. Each string of data must consist of 8 bits of data. In applications where multiple devices are cascaded together, the string of data must consist of 8 bits for each device. A high data bit turns the respective output channel on and a low data bit turns it off. Fault data for the device is clocked out of SDO as serial input data is clocked into the device. Fault data consists of fault flags for the over-battery voltage (bit 8), under-battery voltage (bit 7) (not on TPIC46L03), and shorted/open-load flags (bits 1-6) for each of the six output channels. A logic-high bit in the fault data indicates a fault and a logic-low bit indicates that no fault is present on that channel. Fault register bits are set or cleared asynchronously to reflect the current state of the hardware. The fault must be present when CS\ is transitioned from high to low to be captured and reported in the serial fault data. New faults cannot be captured in the serial register when CS\ is low. CS\ must be transitioned high after all of the serial data has been clocked into the device. A low-to-high transition of CS\ transfers the last 6 bits of serial data to the output buffer, puts SDO in a high-impedance state, and clears and reenables the fault register. The TPIC46L01/L02/L03 was designed to allow the serial input interfaces of multiple devices to be cascaded together to simplify the serial interface to the controller. Serial input data flows through the device and is transferred out SDO following the fault data in cascaded configurations.

For parallel operation, data is asynchronously transferred directly from the parallel input interface (IN0-IN5) to the respective GATE output. SCLK or CS\ are not required for parallel control. A 1 on the parallel input turns the respective channel on, where a 0 turns it off. Note that either the serial interface or the parallel interface can enable a channel. Under parallel operation, fault data must still be collected through the serial data interface.

The predrivers monitor the drain voltage for each channel to detect shorted-load or open-load fault conditions in the on and off states respectively. These devices offer the option of using an internally generated fault-reference voltage or an externally supplied VCOMP for fault detection. The internal fault reference is selected by connecting VCOMPEN to GND and the external reference is selected by connecting VCOMPEN to VCC. The drain voltage is compared to the fault-reference voltage when the channel is turned on to detect shorted-load conditions and when the channel is off to detect open-load conditions. When a shorted-load fault occurs using the TPIC46L01 or TPIC46L03, the channel is turned off and a fault signal is sent to FLT\ as well as to the serial fault-register bit. When a shorted-load fault occurs while using the TPIC46L02, the channel transitions into a low-duty cycle, pulse-width-modulated (PWM) signal as long as the fault is present. Shorted-load conditions must be present for at least the shorted-load deglitch time, t(STBDG), in order to be flagged as a fault. A fault signal is sent to FLT\ as well as the serial fault register bit. More detail on fault detection operation is presented in the device operation section of this data sheet.

The TPIC46L01 and TPIC46L02 provide protection from over-battery voltage and under-battery voltage conditions irrespective of the state of the output channels. The TPIC46L03 provides protection from over-battery voltage conditions irrespective of the state of the output channels When the battery voltage is greater than the overvoltage threshold or less than the undervoltage threshold (except for the TPIC46L03, which has no undervoltage threshold), all channels are disabled and a fault signal is sent to FLT\ as well as to the respective fault register bits. The outputs return to normal operation once the battery voltage fault has been corrected. When an over-battery/under-battery voltage condition occurs, the device reports the battery fault, but disables fault reporting for open and shorted-load conditions. Fault reporting for open and shorted-load conditions are reenabled after the battery fault condition has been corrected.

These devices provide inductive transient protection on all channels. The drain voltage is clamped to protect the FET. This clamp voltage is defined by the sum of VCC and turn-on voltage of the external FET. The predriver also provides a gate-to-source voltage (VGS) clamp to protect the GATE-source terminals of the power FET from exceeding their rated voltages.

These devices provide pulldown resistors on all inputs except CS\. A pullup resistor is used on CS\.

特性

  • 6通道串行輸入/并行輸入低側(cè)預(yù)FET驅(qū)動(dòng)器
  • 器件可以級(jí)聯(lián)< /li>
  • 用于外部功率FET的內(nèi)部55V電感負(fù)載鉗位和V GS 保護(hù)鉗
  • 全部獨(dú)立短路負(fù)載/電池短路故障檢測漏極端子
  • 獨(dú)立斷態(tài)開路故障檢測
  • 電池過壓鎖定保護(hù)和故障報(bào)告
  • TPIC46L01的電池欠壓鎖定保護(hù)和/> TPIC46L02
  • 異步漏極開路故障標(biāo)志
  • 器件輸出可與多個(gè)外部器件進(jìn)行線或通
  • 通過串行輸出端子返回故障狀態(tài)
  • 器件的內(nèi)部全局上電復(fù)位
  • 具有滯后的高阻抗CMOS兼容輸入
  • TPIC46L01和TPIC46L03在發(fā)生短路負(fù)載故障時(shí)禁用門控輸出
  • TPIC46L02在短路負(fù)載故障時(shí)將門輸出轉(zhuǎn)換為低占空比PWM模式rs

參數(shù) 與其它產(chǎn)品相比?低端驅(qū)動(dòng)

? Number of channels (#) Power switch Peak output current (A) Input VCC (Min) (V) Input VCC (Max) (V) Rise time (ns) Fall time (ns) Prop delay (ns) Input threshold Channel input logic Input negative voltage (V) Features Rating Operating temperature range (C) Package Group ? TPIC46L01 6 ? ? MOSFET ? ? 0.0012 ? ? 8 ? ? 24 ? ? 3500 ? ? 3000 ? ? 5000 ? ? CMOS ? ? Non-Inverting ? ? -0.3 ? ? SPI Interface
Sleep Mode
OVP
Fault Diagnostics ? ? Catalog ? ? -40 to 125 ? ? SSOP | 28 ? ?

技術(shù)文檔

數(shù)據(jù)手冊(1)
元器件購買 TPIC46L01 相關(guān)庫存

相關(guān)閱讀

主站蜘蛛池模板: 中国一级生活片 | 人人爽影院 | 成人在线天堂 | 大黄网站在线观看 | 日本特级视频 | 性夜黄 a 爽免费看 性夜黄a爽影免费看 | 欧美乱淫| 色天使在线视频 | 在线成人aa在线看片 | 日日操免费视频 | 欧美两性网 | 日韩精品毛片 | 国产叼嘿网站免费观看不用充会员 | 天堂8在线天堂bt | 2018天天拍拍拍免费视频 | 欧美一级高清免费播放 | 成人在线网 | 在线亚洲综合 | 亚洲第一区视频 | www.亚洲色图.com | 精品国产影院 | 国产一级爱c片免费播放 | 国产老头和美女在线观看 | 国产精品黄网站免费观看 | 午夜色a大片在线观看免费 午夜色大片在线观看 | 最新合集丨新片速递 | 中文字幕在线二区 | 性欧美xxx 不卡视频 | avtt天堂网永久资源 | 黄网免费看 | 天天黄色 | 国产黄色的视频 | 四虎免费影院4hu永久免费 | 国产精品久久久精品三级 | 欧美啪啪小视频 | 福利视频亚洲 | 国模视频一区 | 小泽玛利亚在线观看123 | 黄色三级视频在线观看 | 色综合久久网女同蕾丝边 | 夜夜骚视频|